In this guide, we'll see how a four-stage Cockcroft-Walton multiplier can turn a 2.5 kV peak AC input into an ideal no-load output of 20 kV DC. We'll start with the two stages in Figure 1, where you can trace the charging current through the diodes on each half-cycle and see how the capacitor voltages add up.
Once a load draws current, the capacitors discharge a little between pulses. We'll calculate how far the average output voltage falls, read the voltage ripple from the waveform, and compare the half-wave ladder with a full-wave circuit that recharges the output twice per cycle.
On this page · How the ladder works · Output voltage · Ripple and voltage drop · Four-stage calculation · Full-wave multipliers · Choosing components · Multiplier and driver choices · Measurement
How does a Cockcroft-Walton multiplier work?
A half-wave voltage multiplier circuit uses alternate half-cycles of the AC input to pass charge from one stage to the next. In Figure 1, C1 and C3 form the pumping column on the left. Their junction voltages rise and fall with the input. The diodes steer charge into C2 and C4 in the smoothing column on the right. Those capacitors are in series, so their voltages add up at the output.
Consider the first stage in Figure 1. Near the negative input peak, D1 conducts and charges C1 to approximately the input peak voltage. As the input rises towards its positive peak, the voltage stored on C1 lifts node P1 to approximately twice that peak. D2 then charges C2. The next pair of diodes and capacitors repeats this process at a higher voltage.
We count two diodes and two capacitors as one half-wave stage. Each stage adds about twice the input peak voltage to the no-load output. The circuit above has two stages, so its ideal output is four times the input peak. Reversing all four diodes gives a negative output.
For a given input power, doubling the output voltage halves the current an ideal multiplier can supply. A real ladder loses some of that power in its diodes and capacitors.
Calculating the ideal output voltage
For a symmetrical AC input, the ideal no-load output depends on the number of doubler stages n and the input peak voltage Vp.
\[V_{\mathrm{ideal}}=2nV_{\mathrm{p}}\]
Here, Vp is measured from the input's zero reference to its positive peak. The full swing from the negative peak to the positive peak is Vpp = 2Vp. A two-stage circuit driven by a waveform swinging between −2.5 kV and +2.5 kV therefore has an ideal output of 10 kV.
If the input is a sine wave, you can calculate its peak voltage from its RMS value.
\[V_{\mathrm{p}}=\sqrt{2}\,V_{\mathrm{RMS}}\]
A 2.5 kV peak sine wave is about 1.77 kV RMS and 5 kV peak to peak. A square wave that alternates between the same two peaks has an RMS voltage of 2.5 kV. For an asymmetric flyback pulse, check the voltage swing at the multiplier input with the intended load connected.
Even with the load disconnected, diode forward drops, leakage and stray capacitance can keep the output below the ideal voltage.
Why the output has ripple and falls under load
The load draws charge from the smoothing capacitors, and their voltage falls. On the next charging pulse the diodes conduct and the voltage rises again. The difference between the highest and lowest output voltage in one cycle is the peak-to-peak ripple.
Voltage drop, also called sag, tells us how far the loaded output falls below its no-load value. In Figure 2, the top of the loaded waveform is already 100 V below the ideal 20 kV. From that peak the output falls another 20 V before the next charging pulse.
Estimating ripple and voltage drop
These estimates assume a half-wave ladder with the same capacitance C in every position, a sine-wave input at frequency f and a nearly constant load current I. They apply when the charging pulses are brief and the voltage across each capacitor changes little between pulses.
\[V_{\mathrm{ripple,pp}}\approx\frac{I}{fC}\,\frac{n(n+1)}{2}\]
\[\Delta V_{\mathrm{peak}}\approx\frac{I}{fC}\left(\frac{2n^3}{3}+\frac{n^2}{2}-\frac{n}{6}\right)\]
Here n counts complete doubler stages. With I in amperes, f in hertz and C in farads, both results are in volts. Reinhold and colleagues give the two expressions in equations (4) and (5) of their cascade-rectifier analysis.
Subtracting the peak drop from the ideal voltage gives the highest voltage under load. For the sawtooth in Figure 2, subtract half the peak-to-peak ripple from that value to get the mean.
\[V_{\mathrm{out,mean}}\approx 2nV_{\mathrm{p}}-\Delta V_{\mathrm{peak}}-\frac{V_{\mathrm{ripple,pp}}}{2}\]
Baldisserri and colleagues give the mean directly for a sine-wave input in equation (1) of Section II. Their result agrees with the equation above if you omit the diode-drop term. Subtracting half the ripple again would count it twice.
The calculation assumes the transformer maintains its secondary voltage under load. If that voltage falls, each stage adds less voltage to the output. Losses in the diodes and capacitors, along with stray capacitance, can lower the measured output further.
Why stage count matters so much
The lower stages have to recharge the stages above them as well as supply the load. At the same load current, frequency and capacitance, the ripple grows roughly with n², while the largest term in the peak-drop equation grows with n³.
Under load, an extra stage on a long ladder can add much less than twice the input peak voltage. For example, four stages at 2.5 kV peak and two stages at 5 kV peak both give an ideal 20 kV. The shorter ladder sags less at the same current, frequency and capacitance, but its capacitors, diodes and insulation between stages must withstand twice the voltage per stage.
Calculating the output of a four-stage, 20 kV multiplier
Take a four-stage half-wave voltage multiplier driven by a 2.5 kV peak sine wave at 50 kHz. Every capacitor is 1 nF, and the total DC load current is 100 µA. Start with I/(fC), which appears in both equations.
\[\frac{I}{fC}=\frac{100\times10^{-6}}{50{,}000\times10^{-9}}=2\,\mathrm{V}\]
With n = 4, the ripple coefficient is 10 and the peak-drop coefficient is 50.
| Quantity | Calculation | Result |
|---|---|---|
| Ideal no-load voltage | 2 × 4 × 2.5 kV | 20 kV |
| Peak-to-peak ripple | 2 V × 10 | 20 V pp |
| Drop in the upper level | 2 V × 50 | 100 V |
| Loaded maximum | 20,000 − 100 V | 19.900 kV |
| Approximate mean | 20,000 − 100 − 10 V | 19.890 kV |
| Loaded minimum | 19,900 − 20 V | 19.880 kV |
The calculated mean is 110 V below the ideal voltage, a drop of 0.55%. At 100 µA, the load receives about 1.99 W.
Doubling the current doubles the calculated ripple and voltage drop. Doubling capacitance or frequency halves both terms if the other conditions remain the same.
If the load is a resistor, it draws less current as the output voltage falls. Substitute I = Vout,mean/R into the ripple and voltage-drop equations and solve for the mean output voltage. Include any divider or bleeder connected across the output in the parallel load resistance R.
What does a full-wave Cockcroft-Walton multiplier look like?
A conventional full-wave multiplier, also called a symmetrical multiplier, has two pumping columns, one on each side of a shared smoothing column. Its AC inputs have equal amplitude and opposite phase. When one reaches its positive peak relative to the common return, the other reaches its negative peak.
The pumping columns charge the smoothing capacitors on alternate half-cycles. With equal drive voltages 180° apart, the ripple from one column partly cancels the ripple from the other. In a balanced circuit the remaining ripple repeats twice per input cycle (2f). A mismatch between the columns or their drive voltages leaves more ripple. Ruzbehani illustrates the effect of changing the input phase in Figures 3 and 4 of Section 3.1.
Adding the second pumping column changes how the capacitors charge, so the full-wave circuit uses different equations for ripple and voltage drop. We cannot get those results by doubling f in the half-wave equations.
In Figure 3, the ideal output is still 2nVp. Here Vp is the peak voltage from the centre tap to one end of the secondary. From end to end, the secondary has twice that peak voltage.
The table compares ladders with the same load current, number of stages and capacitor values. Each AC input has the same peak voltage and frequency. Baldisserri and colleagues list the component counts in Table I of their paper.
| Feature | Half-wave | Full-wave |
|---|---|---|
| High-voltage drive | One AC input relative to return | Two equal, opposite-phase inputs relative to a common return |
| When the output capacitors charge | Once per input cycle | Twice per input cycle |
| Ripple and load regulation | Larger ripple and sag as stages or current increase | Lower ripple and sag under comparable operating conditions |
| Components for n stages | 2n diodes and 2n capacitors | 4n diodes and 3n capacitors |
| Construction | Fewer parts and a simpler transformer connection | A split or dual secondary, more parts and more space for wiring and insulation |
| Typical reason to choose it | A simple AC source and a load that draws little current and tolerates some ripple | A steadier DC output or more current within a specified voltage-drop limit |
The extra diodes and capacitors cost more and take up space. To compare efficiency, measure how much power each supply draws at the same DC output voltage and current.
Driving the full-wave ladder
The full-wave ladder is harder to drive because it needs two equal AC voltages of opposite phase. A transformer with a centre-tapped high-voltage secondary supplies both. Its centre tap connects to the grounded return in Figure 3 and its outer ends feed A and B.
For the full-wave ladder in Figure 3, you can use two matching AC flybacks. Both need unrectified secondaries with the same number of turns. Join their secondary return leads at the grounded centre point. The high-voltage lead from one flyback feeds A and the other feeds B.
One half-bridge can drive both flybacks. Use the same number of primary turns on each core and connect the two primaries in parallel across the AC output of the half-bridge. If both transformers are wound alike, swap the two leads on one primary so that A rises as B falls. Winding one primary in the opposite direction instead gives the same result. Each primary sees the full drive voltage, and the half-bridge must carry the combined primary current.
You can also use one half-bridge per flyback. With matching winding polarities, use a common timing source to drive the primaries half a cycle (180°) apart. In either arrangement, when A reaches its positive peak under load, B should reach an equal negative peak relative to the grounded return.
Choosing capacitance, frequency and voltage ratings
| Change | Why it helps | Trade-off |
|---|---|---|
| Increase stage capacitance | The capacitor voltage falls less for each unit of charge drawn | Larger capacitors take up space, store more energy and need more charge at startup |
| Increase frequency | The load has less time to draw charge between pulses | Transformer, diode and capacitor losses can increase |
| Use fewer stages | The lower stages have fewer capacitors to recharge | A higher input voltage is needed for the same output |
| Reduce total load current | Less charge must be replaced each cycle | A bleeder that draws less current takes longer to discharge the capacitors |
Raising the frequency reduces the calculated ripple and sag as long as the input peak stays the same. Connecting the voltage multiplier can shift the transformer's resonant frequency. When adjusting the drive, check the output voltage under load and monitor the temperatures of the transformer and multiplier.
In the ideal half-wave ladder, the first pumping capacitor charges to Vp. The other capacitors charge to about 2Vp, and each diode sees about 2Vp in reverse.
At the top of the 20 kV ladder, one terminal of the smoothing capacitor is at about 15 kV and the other at 20 kV. The capacitor has only 5 kV across it, but it still needs enough space and insulation between its leads and the return conductor, which is at 0 V.
Allow for voltage peaks at startup and when the load disconnects, especially if the circuit rings. Check the capacitors' ripple-current rating and dielectric losses at the drive frequency. Each high-voltage diode must carry the forward charging pulses and withstand the repetitive peak reverse voltage. Slow reverse recovery increases switching losses, and reverse leakage drains charge between pulses.
An output RC filter can smooth the ripple at the load. Its series resistor drops some DC voltage under load, and the filter capacitor takes time to charge through it. A larger capacitor across the output can hold the voltage steadier between pulses, but the lower stages still have to replace the charge the load draws.
Each capacitor stores E = ½CV², where V is the voltage across its terminals. Larger capacitors store more energy at the same voltage. During a short, this stored charge can supply a brief current far above the normal load current. In a Spellman supply, load current heats the series output resistor during normal operation. The resistor also absorbs energy from the capacitors during a short, as Spellman explains in its capacitor-charging note.
The capacitors can stay charged after the driver is switched off. Give each charged section a discharge path and verify that it has discharged before touching the circuit.
Choosing a multiplier, transformer and driver
At High Voltage Experimental (HVE), we offer a 10× high-voltage multiplier module with a choice of positive or negative output. You can connect this half-wave module directly to the unrectified secondary of a standard AC flyback. Its maximum input is 10 kV peak AC, and its nominal frequency range is 20–300 kHz. The module is rated for 100 kV DC at the output. We recommend keeping the output at or below 80 kV per module.
The 10× marking corresponds to five doubler stages. The 50 mA input-current rating applies on the AC side, where the transformer feeds the module.
The 25 kV AC flyback transformer has an unrectified secondary suitable for a half-wave ladder. When using it with the 10× module, keep the voltage at the module input within its 10 kV peak limit. The 80 V, 8 A half-bridge amplifier can drive a suitable primary winding at the frequency set by an external signal.
Measuring the output voltage and ripple
At 20 kV, a 1 GΩ measurement divider draws 20 µA. Connecting it across a load that already draws 100 µA raises the total to about 120 µA, a 20% increase. Add any bleeder current and leakage to that figure when calculating ripple and sag.
Our high-voltage resistor divider guide shows how to choose the divider resistance for the current your source can spare. It also explains how the meter changes the divider ratio and how to keep each resistor within its voltage rating.
A divider can read the DC level accurately and still distort the ripple waveform. Capacitance in the divider and its wiring changes the ratio at higher frequencies unless the divider is properly compensated. Limited bandwidth in the probe or oscilloscope can round off the peaks. The probe can also change the signal at the test point, as Tektronix shows in its square-wave measurements on page 6.
Choose a probe or divider rated for the full DC voltage including the ripple peaks, and for the voltage from each input connection to earth. The full voltage is still present at the probe tip when the oscilloscope is AC coupled. On an earth-referenced oscilloscope, the ground clip is connected to protective earth. Attaching it to a floating high-voltage node would short that node to earth.
If your DC meter reads 19.89 kV, compare that reading with the calculated mean in Figure 2. The peak of the same waveform is 19.90 kV, and the swing from peak to trough is 20 V. When sharing a measurement, give the input waveform, frequency and total load current so someone else can repeat the test. If you're comparing ripple traces, include the probe or divider and the measurement bandwidth. Those details can explain why two setups show different peaks at the same DC voltage.
Common voltage-multiplier questions
Can a Cockcroft-Walton multiplier run from DC?
No, not directly, but you can power the driver from a DC supply. The driver switches the transformer primary to produce the alternating secondary voltage the ladder needs. Applying steady DC directly to the ladder gives it only an initial charging pulse at switch-on.
Does a DC flyback replace the AC transformer?
No. Both circuits shown here need an unrectified AC secondary. Figure 1 charges C1 on the negative swing and C2 on the positive swing. A DC flyback's internal diode blocks current in one direction, as shown in the secondary winding diagram in our AC versus DC flyback guide.
Does full-wave operation produce positive and negative outputs?
No. Both pumping columns in Figure 3 charge the same positive output. Reversing all eight diodes makes that output negative relative to the return.
Technical references
- Reinhold, Truempy and Bill, The Symmetrical Cascade Rectifier. Equations (4) and (5) on page 289 give the voltage drop and peak-to-peak ripple of the half-wave ladder under load.
- Baldisserri and colleagues, Square-Wave-Fed Cockcroft-Walton Voltage Multipliers for Enhanced Design Flexibility in Ionic Propulsion. Equation (1) in Section II gives the mean output voltage of a half-wave ladder driven by a sine wave. Table I compares the component counts of the different circuits.
- Mohsen Ruzbehani, A Comparative Study of Symmetrical Cockcroft-Walton Voltage Multipliers. Figures 3 and 4 in Section 3.1 show the symmetrical full-wave circuit and how the phase of its two inputs affects output ripple.
- Spellman High Voltage, Capacitor Charging and Spellman High Voltage Power Supplies. Application note AN-26 explains how the series output resistor in a Spellman supply limits discharge current and absorbs energy during a short circuit.
- Tektronix, How to Minimize Probe Loading with Low Capacitance Probes. Figure 3 on page 6 compares square-wave measurements made with probes of different input capacitances.





No comments yet. Be the first to start the conversation.